CardioCare 2000

CardioCare 2000

The CardioCare 2000 is an economically priced 12 channel resting ECG that does not compromise on performance. Suitable for use in private practice, the ER, or hospitals use, the CardioCare 2000 is designed for maximum ease of use and convenience. Software upgradeable and networkable, the CardioCare 2000 is an excellent choice for your diagnostic needs.

  • Over 130 kinds of interpretation results based on advanced Minnesota code
  • High-Quality 12ch interpretive ECG at a 3ch price
  • Free S/W upgrade via internet
ECG Leads 10 lead 12 channel simulataneous 10-second resting ECG
Dimension 296 (w) x 305.5 (h) x 92.5 (d) mm
  Approximately 2.98 kg
Recording Channel 3,6,12 channel and 1 channel (60 sec)
Sensitivity 5, 10, 20 auto (I~aVF: 10, V1~V6:5) mm/mV
Printing Speed 12.5, 25, 50 mm/s
Filters AC (50/60 Hz, -20dB or better)
  Muscle (25~35Hz, -3dB or better)
  Base Line Drift (0.1Hz, -3dB or better)
  Low pass filter (off, 40Hz, 100Hz, 150Hz)
Display 2 x 16 character LCD display
LCD display Sensitivity, speed, filter status, HR, printing form, rhythm lead
LED indicator Signal quality, power source, battery
Keyboard Membrane keyboard
  Alphanumeric and symbol available
Patient Data ID, name, age, sex, height, weight
Basic Measurement Heart rate, PR, QRS, QT/QTc, P-R-T axis
Recorder Thermal print head, thermal roll paper
  Report papers:
  -Width: A4: 210mm or 8.5″
  -Length: A4: 300mm or 11″
  Effective writing width: 204mm
  Resolution:
  – Vertical: 8 dots/mm
  – Horizontal: 16 dots/mm
Electrical Internal noise: 20uV(p-p) max
  Input circuit: Floating input
  Isolated and defibrillation protected
  Input impedance: >10MQ
  Input range: > +/- 5mV
  Common Mode Rejection: > +100dB
  DC offset voltage: > +/- 300mV
  Time constant: 3.2 sec
  Patient leakage current: <10uA
  Frequency response: 0.05~150Hz
Signal qualilty control Disconnected lead detection
Power Power Supply: AC or built-in Battery (option)
  Power requirement: 100 – 240 Vac, 50/60Hz, 1.0 – 0.5A
  Power consumption: 60w max
Battery capacity 1 hour of normal use (approximately 100 automatic ECG printouts)
Communication PC connection with RS-232 interface and LAN
Safety Class 1, Type BF
Conformity CE, CSA
Environment Operating humidity: 30~85%
  Operating temperature: 10° ~40° C
  Atmospheric pressure: 70 ~ 106 KPa
Standard accessory Power Cable – 1 ea.
  Patient Cable – 1 ea.
  Electrode – 10 ea.
  Chart Paper – 1 ea.
  Operation Manual – 1 ea.
Options Rechargeable Battery (ni-mh)
  Cart
  Hanger
  Bag
  PC s/w
  Limb electrode
  Chest electrode
  RS-232C null cable
  LAN cable (Ethernet-RJ-45)